Mar 11, 2023

Effective measures to prevent compressor failures in industrial water chillers

Although various industrial water chillers produced in China are imported and have a long service life, in the actual use process, if users do not carefully maintain and maintain the use of industrial water chiller compressors, different degrees of failures will also occur, seriously affecting the performance of the entire industrial water chiller. Effective measures to prevent compressor failures in industrial water chillers:
1. Routine testing
During the use of industrial water chillers, it is necessary to always pay attention to the issue of compressor operating noise. If there is a significant increase in noise, based on the experience introduced by the factory cooling plant, it is necessary to timely and effectively complete shutdown inspection, and complete the maintenance work of the industrial cooling compressor on the basis of ensuring normal operation. Note: Once the compressor makes noise, it is necessary to be vigilant. Often minor problems can cause complex and serious faults in the later stage, such as compressor fluid hammer.
2. Pay attention to the pressure gauge
During the use process, the specific value of the pressure gauge of the industrial water chiller needs to be noted at any time. If there is a large range of abnormal conditions, it is necessary to carefully inspect them. The specific inspection method can be based on the relevant methods introduced by the domestic industrial water chiller manufacturer, and all inspection processes can be completed to avoid pressure problems that affect the specific working efficiency of the industrial water chiller compressor, resulting in an increase in power consumption, Improve energy consumption of industrial water chillers. Note: There are high-pressure pressure gauges and low-pressure pressure gauges for water chillers.
3. Measuring the operating temperature
During the operation of industrial water chillers, it is necessary to measure the specific operating temperature of the industrial control water chiller compressor by hand or equipment at any time. If the temperature is too high, it means that the industrial water chiller is in an overloaded operation state. At this time, it is necessary to measure the current and voltage to achieve the purpose of fault detection, so as to ensure that the industrial water chiller compressor is in an absolutely safe operating state and reaches an appropriate operating temperature, Complete the entire operation process. Note: If the compressor temperature is too high, it may also be caused by too little fluorine content, too low compressor power, too long capillary tubes, poor condensation effect, temperature control failure, and compressor oil shortage, which is very harmful. Special attention should be paid.
During the repair process of the water chiller, the main task is to check whether the repaired components have reached the required accuracy, and whether the maintenance is carried out according to the repair scale and scope.