Commercial Rooftop Air Conditioner

Commercial Rooftop Air Conditioner

Feizhong commercial rooftop air conditioner has constant temperature and humidity functions, which can meet the requirements of high temperature and humidity places. The constant temperature and humidity roof air conditioner is a craft air conditioner. The entire series of products has wide energy coverage, even grading, and strong optionality. The air volume and static pressure can be adjusted appropriately. According to customer needs, the "temperature and humidity accuracy" range can be selected as follows:

PERFORMANCE:
Constant Temperature and Humidity Type
Cooling Capacity Range: 12kW - 453.7kW
Heating Capacity Range:6——216kW (electrical heating)
Temperature Range: 18~27℃, Accuracy Range: ±1.0~2.0℃
Humidification Amount:4-82KG/H
Humidity Range: 50~70%RH, Accuracy Range: ±5~10%RH
Air Flow Range:3000 m3/h to 73000 m3 /h
Refrigerant:R22/R407C
Support OEM/ODM Service
Brand:Feizhong
Send Inquiry

Product Introduction Technical Parameter

 

Commercial Rooftop Air Conditioner

Feizhong the best commercial rooftop hvac units' heating methods include: heat pump heating, electric heating, steam heating, hot water heating, gas heating, etc.; humidification methods: electrode humidification, dry steam humidification, electric humidification, high-pressure micro mist humidification, and wet film Humidification etc.

The hvac roof top unit can add a flow equalization section, a medium-efficiency filter section, a silencer section, and an air outlet section. Generally speaking, conventional new roof ac unit located on the roof have horizontal return air and horizontal air supply: side return air, end air supply; end return air, end air supply; other air return and return methods: side return air, bottom air supply wind; bottom return air, end supply air, etc.

 

Features

 
 
01
 

Wide Application

This series of rooftop air handler includes constant humidity, cooling and heating, heat pump and other varieties. The constant temperature and humidity type hvac unit rooftop unit can meet the needs of places with high temperature and humidity requirements. The cooling and heating type rooftop aircon can meet the needs of comfortable places. The heat pump type roof unit can be used for two purposes in one machine, saving heating operation costs.

 
02
 

Save Investment

The on roof air conditioners is placed on the roof or in an outdoor open space, eliminating the need for a machine room and saving effective space. The unit does not require water pumps, cooling towers, fan coils and other supporting equipment, saving initial investment.

 
03
 

Easy To Install

The rooftop condensing unit does not need to be equipped with refrigerant pipes, cooling water pipes, air ducts, and power supply on site, and it can be used immediately, saving on-site construction time and costs.

1

 

 
04
 

High Efficiency And Energy Saving

The rooftop cooling unit is stable and uses high-performance scroll or screw compressors with high volumetric efficiency and energy efficiency ratio. The screw compressor can easily achieve four-stage or stepless energy adjustment and has high partial load efficiency; expansion valves, filters, solenoid valves and other refrigeration accessories They all use imported brands from the United States, Italy, etc.the roof top aircon does not require secondary refrigerant, and the system efficiency is high.

 
05
 

Run Quietly

The air con on roof unit adopts high-performance scroll or screw compressor and operates smoothly. The roof air con is placed outdoors and only needs to be equipped with air ducts indoors, so the indoor noise is small.

 
06
 

Reasonable Structure

The top plate of the 6 ton rooftop unit adopts a special structure to ensure that water does not enter the roof ac unit. The door panel is made of polyurethane foam to ensure heat insulation performance. The electrical box adopts a sealed structure to ensure the safety of the electrical appliances. The power wiring is placed inside the electrical box, eliminating the risk of roof leakage.

3
 
07
 

Operational Safety

The new rooftop ac unit is equipped with high-voltage, low-voltage, overload, short-circuit, phase failure, overheating, under-wind pressure and other protections, as well as fire damper chain protection.

 
08
 

Intelligent Control

The rooftop ac heat unit adopts advanced control instruments, which can be equipped with two-hand operators and are placed in the outdoor unit and indoor control room. It is very convenient to use and operate. The instrument is equipped with RS485 interface for remote control.

 
09
 

Convenient Function Expansion

The aircon on roof unit is equipped with a variety of functional sections, which can easily realize functions such as air cooling, dehumidification, heating, humidification, filtration, and fresh air ventilation.

2

 

Application

shopping malls, restaurants, entertainment, office buildings, halls and general industrial workshops as well as pharmaceutical, food, electronics, chemical industry, scientific research, machinery and other industrial workshops.

11111111

Send Inquiry

We have an advanced technical team and a professional after-sales department that can provide 24-hrs online consulting services.

We warmly welcome you to wholesale customized chiller made in China here from our factory.

Pls contact us for more details.

Hot Tags: commercial rooftop air conditioner, China commercial rooftop air conditioner manufacturers, suppliers, factory, best rooftop ac unit, commercial rooftop air conditioner, best commercial rooftop hvac units, commercial hvac rooftop units, rooftop commercial air conditioning units, commercial rtu hvac

Performance Model

WKHF

012

WKHF

025

WKHF

055

WKHF

065

WKHF

085

WKHF

110

WKHF

130

WKHF

165

WKHF
195

WKHF

220

WKHF

260

WKHF

290

WKHF

325

WKHF

350

WKHF

400

WKHF

450

Cooling Capacity kW 12 25.3 55.6 64.8 82.7 111.2 129.6 166.8 194.4 222.3 259.2 287.1 324.1 351.9 398.2 453.7
104kcal/h 10.3 21.8 47.8 55.7 71.1 95.6 111.5 143.4 167.2 191.2 222.9 246.9 278.7 302.6 342.5 390.2
Energy Regulation % 0,100 0,50,100 0,33,66,100 0,25,50,75,100
Heating Capacity Electric Heating Type Electrothermic Type
Power kW 6 12 32 36 48 64 72 96 108 120 132 144 156 162 186 216
Hot Water Heating Heating Capacity kW 16 22 55 65 85 110 125 160 190 200 240 260 300 320 360 400
Inlet/Outlet Pipe Diameter DN DN25 DN32 DN40 DN50 DN65 2-DN50 2-DN65
Steam Heating Heating Capacity kW 21 30 60 70 90 120 140 180 210 240 280 310 350 380 430 490
Inlet/Outlet Pipe Diameter DN DN25 DN32 DN40 DN50 DN65 2-DN50 2-DN65
Humidifier Type Electrode Type
Humidification kg/h 4 4 15 25 25 35 45 65 82 82 82 82 82 82 82 82
Power kW 3 3 11.25 18.75 18.75 26.25 33.75 48.75 61.5 61.5 61.5 61.5 61.5 61.5 61.5 61.5
Air Volume m3/h 3000 6000 10000 12000 15000 20000 24000 30000 36000 40000 48000 52000 56000 62000 68000 73000
External Static Pressure Pa ≥250 ≥250 ≥300 ≥300 ≥400 ≥500 ≥500 ≥550 ≥600 ≥600 ≥650 ≥650 ≥700 ≥700 ≥800 ≥800
Temperature Range And Accuracy Temperature Control Range 18 ~27℃,Accuracy±1.0~2.0℃
Humidity Control Range And Accuracy %RH Humidity Control Range 50~70%,Accuracy±5~10%
Power Supply   380V,50Hz,3-phase 5-wire system
Rated Power kW 14.4 24.8 65.15 80.95 100.35 135.75 161.15 216.05 251.1 279.7 303.4 327.2 360.5 380.1 433.1 472.7
Compressor Type Fully Enclosed Scroll Type Semi-Enclosed Screw Type
QTY 1 1 2 2 2 4 4 4 6 1 1 1 1 1 2 2
Nominal Input Power kW 4.05 7.5 17.4 20 25.9 35 40 51.8 60 73.1 82.4 90.7 104 114.6 136.6 146.2
Refrigerant Type R22/R407C
Throttling Mode Thermal Expansion Valve
Evaporator Type Aluminum Finned Copper Tube
Fan Type Double Inlet Centrifugal Fan
Power kW 0.8 1.5 3 4 5.5 7.5 11 15 15 18.5 18.5 22 30 30 37 37
Condensate Fan Type Low Noise Axial Flow Type
QTY 1 2 2 2 2 4 4 6 6 6 6 6 6 8 8 8
Power kW 0.55 0.8 1.5 2.2 2.2 3 4.4 4.5 6.6 6.6 9 9 9 12 12 12
Air Filter Type Plate Initial Effect
Dimensions L*W*H mm Can Be Customized According To Customer Requirements
Weight kg 450 750 1500 1580 1750 2550 2750 3750 4050 4850 5750 5800 6050 7100 7350 7650

 

Noted: Unit Nominal Operating Conditions
Indoor Side Outdoor Side
Dry Bulb Temperature Wet Bulb Temperature Dry Bulb Temperature Wet Bulb Temperature
27℃ 19℃ 35℃ 24℃

1,The hot water inlet temperature is 90°C and the steam pressure is 0.2Mpa

2,Specifications and parameters are subject to product improvement or update without prior notice.